Technical data
* Computer-simulated photometrics
PRODUCT DESCRIPTION
LUMINAIRE TYPE
Wall mounted luminaire. IP rating IP 65

MATERIAL CHARACTERISTICS
Ghost is a lighting void that is obtained from a polypropylene housing anchored to the retaining panels before pouring the concrete. Ghost is composed of two elements: the housing and the lighting element. The housing is in aluminium and it consists of two complementary parts: - A jig , which forms the housing, and is extracted together with the retaining panel after completing the casting and removing the anchor screws; - The housing that remains embedded inside the casting and houses the lighting element. (The housing is supplied with bolts, locking system and stickers to be applied on the outside of the retaining panels so to secure a perfect alignment for multiple installations of each housing when pouring the concrete). The lighting element in die cast aluminum is anchored to the casing through proper screws and it remains completely hided into the void. Mechanical resistance IK 10

INSTALLATION AND MAINTENANCE
This luminaire is manufactured on site during the concrete casting of the wall with hand crafted procedures; therefore, small imperfections caused by the low accurance of the casting, subsidence of the concrete surface, actual and future cracks, colour ripples and variations over time, will be deliberately present and they are a feature of the concrete, proving the hand-made manufacturing procedure. All the versions of Ghost Linear can be connected as a continuous line to obtain a running blade of light. Using the standard Ghost Linear lengths available in the catalogue it is is possible to achieve any specified length and never be more than 22cm from the required length of the concrete structure. We recommend using the longer lengths of Ghost Linear and ending the run with the shorter versions and finish each run with the end caps provided with the luminaires (please allow for at least 5cm of complete wall either end of the concrete void). As an accessory a drilling jig is available for each size of recessed profile of Ghost Continuous line, so to facilitate its alignment to the shutter. Only one drilling jig is required for each size of profile utilized.Considering that “Running” Ghost Linear continuous line is a linear void of 9cm in depth. We suggest to consult a structural engineer in order to calculate an adegate reinforced concrete structure and dimension.
LIGHTING PERFORMANCE
Toughened glass diffuser. LOR --

WIRING
Supplied with a pre-wired 6m H05RN-F cable. Isolation: CLASS II . Available colours: Cast cement. Weight: 2.686 Kg Glow Wire test: --
LED module included

GHOST PATENTED, REGISTERED DESIGN

This luminaire contains built-in LED modules. In case of damage or malfunction please contact the manufacturer to receive additional instructions on how to replace and relative spare parts to order. The LED modules cannot be handled in the luminaire by the end user.

This product contains a light source of energy efficiency class (EPREL - European Product Registry for Energy Labelling): D.

LED modules are engineered accordingly to the existing regulations of Lumen Maintenance (LM80) and Technical Memorandum (TM21), where uniformity and quality of the light is 70,000 hours referred to L80 B10 Ta 25 ° C (50,000 hours referable to L80 B10 Ta 40°C). Lifespan of the luminaire min. 70.000 hours Ta 25°C, min. 50,000 hours at 40°C. Performance Ambient temperature Tq 25°C. Operating ambient temperature range is from -20°C to +50°C. Storage temperature range from -20°C to +60°C.

ELECTRONIC EQUIPMENT SENSITIVE TO OVERVOLTAGE.
We recommend installing surge protection devices "SPD" in the electrical system. Protection devices prevent the intensity of these phenomena’s, protecting the appliances from the risk of being damaged and extending the lifespan. Outdoor luminaires are subject to all types of permanent, temporary, or transient electrical disturbances. Such disturbances can create permanent damage or failure affecting its performance and durability. The surge protection device (supplied by SIMES) is utilized to limit the destructive effect of these phenomena. We suggest that each luminaire must be connected to one protection device at not more than 10m away. For correct coordination of the protections, a surge protection device must also be provided inside the electrical panel of the system (the selection of this device must be carried out from the electrical designer and is not supplied by SIMES).
GHOST LINEAR L 430
Art. C.8036N
MODULE LED 4000K
Light Source Technical Data
Light source type: LED
Colour temperature: 4000K
Rated module luminous flux: 1320lm
Rated luminaire luminous flux: 555lm
Rated module power: 5W
Rated luminaire power: 7.5W
Luminaire efficacy: 74lm/W
ULR: 0%
BUG: B0 - U0 - G0
CIE Flux Code: 47 79 96 100 100
Color Rendering Index: CRI 80
Standard Deviation Color Matching: MacAdam step 3
Power Supply Technical Data
Voltage (AC): 220-240Vac
Frequency (AC): 50/60Hz
Voltage (DC): 176-264Vdc
Dimmable: NOT DIMMABLE (ON-OFF)
Inrush Current: 27A 250µsec
Max. quantity of fixtures for Minature Circuit Breaker type B16A: 27
Max. quantity of fixtures for Minature Circuit Breaker type C16A: 45
Surge protection (between L-N): 1÷2kV
Surge protection (between L/N-PE): 2kV
Temperature and life time Technical Data
LED Lifetime: L80 B10 70.000h Ta 25°C L80 B10 50.000h Ta 40°C
Lifespan of the LUMINAIRE: min. 70.000h Ta 25°C min. 50.000h Ta 40°C
Performance ambient temperature: Tq 25°C
Operating ambient temperature range: da -20°C a +50°C
Storage temperature range: da -20°C a +60°C
Technical Installation Data
Electrical insulation class: II
Protection class IP: IP65
Mechanical resistance: IK10
Weight: 2.686Kg
Power cable: 6m - H05RN-F
Design tools
Professional tools only for registered users Register here
2D and 3D models
BIM
.DXF
.LCF
.3DS
.RFA+TXT
LIGHT CALCULATION
PHOTOMETRIES
DOWNLOAD
loading zip file ...
Accessories
S.2499
SURGE PROTECTION DEVICE 10kV CLASS II
Compatible with all lighting fixtures and electronic ballast accessories classified under electrical Protection Class II Rated voltage 230-277V SPD type 2+3 Max Surge Protection 10kV IP67
S.2495
DALI2 RELAY SWITCH for ON-OFF (NOT DIMMABLE) 230V LUMINAIRES
Allows to make a remote controll of ON-OFF not dimmable 230V luminaires via DALI2 protocol. IP20 Max nominal load 1000VA Max switching current 8A Max inrush current 80A Dimensions 32,5mm x 15mm x 58,5mm NB: the Luminaire can be controlled remotely in ON-OFF mode only and not in dimmed mode.
S.2496
DALI2 RELAY SWITCH for ON-OFF (NOT DIMMABLE) 230V LUMINAIRES
Allows to make a remote controll of ON-OFF not dimmable 230V luminaires via DALI2 protocol. IP67 Max nominal load 1000VA Max switching current 8A Max inrush current 80A Dimensions 175,5mm x 86,5mm x 43mm NB: the Luminaire can be controlled remotely in ON-OFF mode only and not in dimmed mode.
C.8035
Drilling jig for shutter
The template for drilling facilitates the alignment of the recessed profile of Ghost Continuous Line. You require only one template for each size which can be used. again.
C.8035
Drilling jig for shutter
The template for drilling facilitates the alignment of the recessed profile of Ghost Continuous Line. You require only one template for each size which can be used. again.