Loading...
Technical data
* Computer-simulated photometrics
PRODUCT DESCRIPTION
LUMINAIRE TYPE
Wall mounted luminaire. IP rating IP 65

MATERIAL CHARACTERISTICS
Ghost for cladding can also be easily installed into plasterboard panels for indoor or outdoor. The fixture housing is fixed to the back wall that will later be covered with plasterboard panels and subsequently rendered over. The fixtures aperture can also be plastered so to integrate it completely. Ghost for cladding has also been engineered to take many different types of material finish ( mosaic finish, ceramic tiles, stone finish ) that can be contained within the thickness of the protruding edges of the housing (see above diag). Please take extra care during installation that the cut away made to house the recess box is suitable to guarantee a perfect flush finish between the fixture and the wall. Procedure for Plasterboard or exterior fibre cement siding panel: 1. Position the conduit for the electrical feed. 2. Fix the product to the plasterboard panel. 3. Cover the gaps between the panels with a mesh and plaster over. 4. Complete the surface finish. 5. The fixture is supplied with a slanted front panel accessory in anodised aluminium. For indoor applications this panel can be removed and then finished in plasterboard; for outdoor applications we suggest to use this panel (a 19mm recess depth has been provided for the final finish if the panel is not used). 6. Once the plaster is dry you can fit the LED profile into the void. This is the procedure for other walls built on site: 1. Cut away and position the conduit for the electrical feed; 2.Create a niche and recess the fixture housing and align correctly; 3. Cement the housing into the niche and use a gripping mesh to cover both the wall and the housing; 4. Cement the fixtue into the wall, cut the gripping mesh around the fixtures aperture and continue with the finish by applying the relative material to the slanted aperture (19mm recess depth has been provided for the final finish if the panel is not used). 5.The fixture is supplied with an anodised aluminium front panel. You can decide to use this panel so to have a complete aperture in anodised aluminium or without so to render the aperture in the same material finish as the rest of the surface. 6. Once the cladding is dry you can fit the LED profile into the void.
Mechanical resistance IK 10

LIGHTING PERFORMANCE
Toughened glass diffuser. LOR --

WIRING
Supplied with a pre-wired 6m H05RN-F cable. Isolation: CLASS II . Weight: 2.8247 Kg Glow Wire test: --
LED module included

Ghost for cladding PATENTED, REGISTERED DESIGN

This luminaire contains built-in LED modules. In case of damage or malfunction please contact the manufacturer to receive additional instructions on how to replace and relative spare parts to order. The LED modules cannot be handled in the luminaire by the end user.

This product contains a light source of energy efficiency class (EPREL - European Product Registry for Energy Labelling): D.

LED modules are engineered accordingly to the existing regulations of Lumen Maintenance (LM80) and Technical Memorandum (TM21), where uniformity and quality of the light is 70,000 hours referred to L80 B10 Ta 25 ° C (50,000 hours referable to L80 B10 Ta 40°C). Lifespan of the luminaire min. 70.000 hours Ta 25°C, min. 50,000 hours at 40°C. Performance Ambient temperature Tq 25°C. Operating ambient temperature range is from -20°C to +50°C. Storage temperature range from -20°C to +60°C.

ELECTRONIC EQUIPMENT SENSITIVE TO OVERVOLTAGE.
We recommend installing surge protection devices "SPD" in the electrical system. Protection devices prevent the intensity of these phenomena’s, protecting the appliances from the risk of being damaged and extending the lifespan. Outdoor luminaires are subject to all types of permanent, temporary, or transient electrical disturbances. Such disturbances can create permanent damage or failure affecting its performance and durability. The surge protection device (supplied by SIMES) is utilized to limit the destructive effect of these phenomena. We suggest that each luminaire must be connected to one protection device at not more than 10m away. For correct coordination of the protections, a surge protection device must also be provided inside the electrical panel of the system (the selection of this device must be carried out from the electrical designer and is not supplied by SIMES).
GHOST L 240
Art. C.8334W
MODULE LED 3000K
Light Source Technical Data
Light source type: LED
Colour temperature: 3000K
Rated module luminous flux: 574lm
Rated luminaire luminous flux: 266lm
Rated module power: 2.5W
Rated luminaire power: 4W
Luminaire efficacy: 67lm/W
ULR: 0%
BUG: B0 - U0 - G0
CIE Flux Code: 46 78 96 100 100
Color Rendering Index: CRI 80
Standard Deviation Color Matching: MacAdam step 3
Power Supply Technical Data
Voltage (AC): 220-240Vac
Frequency (AC): 50/60Hz
Voltage (DC): 176-264Vdc
Dimmable: NOT DIMMABLE (ON-OFF)
Inrush Current: 27A 250µsec
Max. quantity of fixtures for Minature Circuit Breaker type B16A: 27
Max. quantity of fixtures for Minature Circuit Breaker type C16A: 45
Surge protection (between L-N): 1÷2kV
Surge protection (between L/N-PE): 2kV
Temperature and life time Technical Data
LED Lifetime: L80 B10 70.000h Ta 25°C L80 B10 50.000h Ta 40°C
Lifespan of the LUMINAIRE: min. 70.000h Ta 25°C min. 50.000h Ta 40°C
Performance ambient temperature: Tq 25°C
Operating ambient temperature range: da -20°C a +50°C
Storage temperature range: da -20°C a +60°C
Technical Installation Data
Electrical insulation class: II
Protection class IP: IP65
Mechanical resistance: IK10
Weight: 2.8247Kg
Power cable: 6m - H05RN-F
Design tools
Professional tools only for registered users Register here
2D and 3D models
BIM
.DXF
.LCF
.3DS
.RFA+TXT
LIGHT CALCULATION
PHOTOMETRIES
Elumdat
--
DOWNLOAD
loading zip file ...
Accessories
S.2499
SURGE PROTECTION DEVICE 10kV CLASS II
Compatible with all lighting fixtures and electronic ballast accessories classified under electrical Protection Class II Rated voltage 230-277V SPD type 2+3 Max Surge Protection 10kV IP67
S.2495
DALI2 RELAY SWITCH for ON-OFF (NOT DIMMABLE) 230V LUMINAIRES
Allows to make a remote controll of ON-OFF not dimmable 230V luminaires via DALI2 protocol. IP20 Max nominal load 1000VA Max switching current 8A Max inrush current 80A Dimensions 32,5mm x 15mm x 58,5mm NB: the Luminaire can be controlled remotely in ON-OFF mode only and not in dimmed mode.
S.2496
DALI2 RELAY SWITCH for ON-OFF (NOT DIMMABLE) 230V LUMINAIRES
Allows to make a remote controll of ON-OFF not dimmable 230V luminaires via DALI2 protocol. IP67 Max nominal load 1000VA Max switching current 8A Max inrush current 80A Dimensions 175,5mm x 86,5mm x 43mm NB: the Luminaire can be controlled remotely in ON-OFF mode only and not in dimmed mode.